Sign In | Join Free | My frbiz.com |
|
Model Number : PTN 970
Type : Enterprise Router
Place of Origin : Beijing, China, guangdong, China
Brand Name : HW
Use : All
Products Status : Stock
Function : SNMP, VLAN Support
WAN Ports : 1
Weight (lb/kg) fully configured : 5 kg
Throughput : 1.44 Tbps
Operating temperature : 32° to 104° F (0° to 40° C)
Traffic analysis : NetStream
VLAN : Adding access, trunk, and hybrid interfaces to VLANs/Default VLAN
Dimensions (H x W x D) : 88.9 mm*220 mm*442 mm
Packaging Details :
1,Carton packing or wooden case packing according to customer requirements
2,Sufficient protective materials are added to the packing box to effectively prevent the product from being damaged due to turbulence during transportation.
Supply Ability : 1000 Carton/Cartons per Day
MOQ : 2 pieces
Price : $1,200.00/pieces >=2 pieces
Height [mm] | 88.9 mm | ||||
Depth [mm] | 220 mm | ||||
Wide [mm] | 442 mm | ||||
Chassis height [U] | 2U | ||||
Weight without packaging (full configuration) | 9.4 kg (20.73 lb) | ||||
Typical power consumption (with configuration) [W] | Typical power consumption of 120 G system: 2*10GE+8*GE(o)+8*GE(e)+16E1 Typical Power consumption: 172 W Typical power consumption of 190 G system I: 2*50GE+2*25G+2*10G+16*GE(o) Typical Power consumption: 237 W Typical power consumption of 190 G system II: 2*50GE+4*10G+8*GE(o)+16E1 Typical Power consumption: 211 W Typical power consumption of 190 G system III: 2*50GE+2*10G+8*GE(o)+16E1 Typical Power consumption: 210 W | ||||
Heat dissipation mode | Air cooling | ||||
Typical heat dissipation (with configuration) [BTU/h] | Typical configuration of the 120 G system: 2*10 GE + 8*GE (o) + 8*GE (e) + 16E1 Heat dissipation 558 BTU/hour Typical configuration of the 190 G system: 2*50 GE+2*25G+2*10 G+16*GE (o) Heat dissipation 768.9 BTU/hour Typical configuration of the 190 G system: 2*50 GE+4*10 G+8*GE (o)+16E1 Heat dissipation 684.6 BTU/hour Typical configuration of the 190 G system: 2*50 GE+2*10 G+8*GE (o)+16E1 Heat dissipation 681.3 BTU/hour | ||||
Power supply mode | DC | ||||
Input voltage range [V] | -38.4 V to -72 V | ||||
Rated input voltage [V] | –48 V/–60 V | ||||
Maximum input current [A] | 10 A | ||||
Number of slots | 11 | ||||
Redundant fans | The device can run at the temperature of 40˚C in the short term after a single fan fails. | ||||
Redundant CXPs | 1+1 | ||||
Redundant power supply | 1+1 | ||||
Noise at normal temperature (acoustic power) | 55dB(A)@normal temperature | ||||
Maximum input cable size | 4 mm² (10 meters) | ||||
Front-end circuit breaker/fuse | ≥16 A | ||||
Restriction on the operating temperature variation rate | 30°C/hour (86°F/hour) | ||||
Long-term operating temperature | -20°C to 60°C(-4.0°F to 140.0°F) | ||||
Storage temperature | -40°C to 70°C(-104.0°F to 158.0°F) | ||||
Long-term operating relative humidity [RH] | 10% RH to 90% RH, non-condensing | ||||
Storage relative humidity [RH] | 10% RH to 100% RH, non-condensing | ||||
Long-term operating altitude | ≤ 4000 m. When the altitude is between 1800 m and 4000 m, the device operating temperature decreases by 1 °C every time the altitude increases by 220 m. | ||||
Storage altitude | < 5000 m(< 16404.2 ft.) | ||||
MTBF [year] | 40 | ||||
MTTR [h] | 2 | ||||
Availability | 0.99999 | ||||
MTTR [h] | 2 | ||||
Availability | 0.99999 |
![]() |
32° to 104° F 0° to 40° C Compatible OptiX PTN 970 Assembly Classis DC Router Machine Images |